^ Back to Top

Sistemi per il trattamento dell'acqua
      water system treatment

Guide to selection of the product

After considering the different quality standards proposed and what the many varied demands of the market, it may be useful a guide for choosing the right product for a specific application. Here we outline below the main demands matched to the standard and the product of choice

 

PURE LAB WATER

APPLICATION PURITY GRADE MODEL


 High precision laboratory analysis
 Analysis trace metals
 Biology Molecular Microbiology
 electrophoresis
 Ion exchange chromatography
 Mass Spectrometry
 Atomic-absorption spectrophotometry
 TOC
 HPLC chromatography
 Cell cultures
 DNA sequencing
 PCR


QUALITY STANDARD

ISO 3696: grade 1
ASTM: type 1
NCCLS: type 1

EL. RESISTIVITY SPEC. 25°C

18,2 MOhm.cm


UPW refiner

UPW refiner fr


  Spectrophotometric analysis in 
  the atomic absorption
  HPLC chromatography
  Colorimetric analysis and qualitative
  Preparation / dilution reagents
  Power systems for ultra-pure water,
  autoclaves, boilers in general.
  Glassware washer supply
  Power steam generators
  Ultrasonic, thermostatic baths

QUALITY STANDARD

ISO 3696: grade  2
ASTM: type 2
NCCLS: type 2
EP: conform

EL. RESISTIVITY  SPEC. 25°C
10 - 18,2 MOhm.cm

OSMO LAB UPW2


DEMI VERSION - /d
  General laboratory use
  Colorimetric analysis and qualitative
  Preparation / dilution reagents
  Glassware rinsing
  Thermostatic baths power
  Devices that require power
  Demi water under pressure

  Analysis in which also is required
  Microbiological cover (W/ FILTER
  ANTI BACTERIA OPTIONAL

DEMI 2 VERSION - /d2
Spectrophotometric analysis in 
  the atomic absorption
  HPLC chromatography
  Colorimetric analysis and qualitative
  Preparation / dilution reagents
  Power systems for ultra-pure water,
  autoclaves, boilers in general.
  Glassware washer supply
  Power steam generators
  Ultrasonic, thermostatic baths


QUALITY STANDARD

ISO 3696:
base and demi version: grade  3
demi2 version: grade 2

ASTM
base and demi version: type 3
demi2 version: type 2

NCCLS
base and demi version: type 3
demi2 version: type 2

EP: conform

EL: RESISTIVITY SPEC. 25°C
base and /d version: 1-5 MOhm.cm
/d2 version: 10-18 MOhm.cm

OSMO LAB 2 


DEMI VERSION - /d
  General laboratory use
  Colorimetric analysis and qualitative
  Preparation / dilution reagents
  Glassware rinsing
  Thermostatic baths power
  Devices that require power
  Demi water under pressure

  Analysis in which also is required
  Microbiological cover (W/ FILTER
  ANTI BACTERIA OPTIONAL

DEMI 2 VERSION - /d2
Spectrophotometric analysis in 
  the atomic absorption
  HPLC chromatography
  Colorimetric analysis and qualitative
  Preparation / dilution reagents
  Power systems for ultra-pure water,
  autoclaves, boilers in general.
  Glassware washer supply
  Power steam generators
  Ultrasonic, thermostatic baths


QUALITY STANDARD

ISO 3696:
base and demi version: grade  3
demi2 version: grade 2

ASTM
base and demi version: type 3
demi2 version: type 2

NCCLS
base and demi version: type 3
demi2 version: type 2

EP: conform

EL: RESISTIVITY SPEC. 25°C
base and /d version: 1-5 MOhm.cm
/d2 version: 10-18 MOhm.cm

OSMO LAB 3
(
ita)





  General laboratory use
  Colorimetric analysis and qualitative
  Preparation / dilution reagents
  Glassware rinsing
  Thermostatic baths power
  Devices that require power
  Demi water under pressure



QUALITY STANDARD

ISO 3696: grade  3
ASTM: type 3
NCCLS: type 3
EP: conform

EL. RESISTIVITY SPEC. 25°C
5 MOhm.cm

OSMO LAB pr 20 



 BASE VERSION
 Power systems for ultrapure water, 
 autoclaves, boilers in general. 
 Glassworks rinsing 
 Power supply steam generators 
 Ultrasound, thermostatic baths

 DEMI VERSION
 General laboratory use
 Colorimetric analysis and qualitative
 Preparation / dilution reagents
 Glassware rinsing
 Thermostatic baths power
 Industrial uses: preparation waters
 of process

 DEMI2 VERSION
 Spectrophotometric analysis in the
 atomic absorption
 HPLC chromatography
 Colorimetric analysis and qualitative
 Preparation / dilution reagents
 Feeding for water systems
 Ultra-pure, autoclaves, boilers in
 general.

 Glassware washer supply
 Power steam generators
 Ultrasonic, thermostatic baths




QUALITY STANDARD

RO VERSION (reverse osmosi only)

purified water, produced only
with reverse osmosis system.

DEMI VERSION

ISO 3696: grade  3
ASTM: type 3
NCCLS: type 3

DEMI2 VERSION

ISO 3696: grade 2
ASTM: type 2
NCCLS: type 2
EP: conform

EL. RESISTIVITY SPEC. 25°C

Demi Vers. 5 MOhm.cm
Demi2 Vers. 10-18 MOhm.cm


RO CUBIC-S2

RO CUBIC-S3/d-d2

models equipped with
24VDC power supply
external with conf.

CE ed EAC


 Power systems for ultrapure water, 
 autoclaves, boilers in general. 
 Glassworks rinsing 
 Power supply steam generators 
 Ultrasound, thermostatic baths

QUALITY STANDARD
purified water, produced only
with reverse osmosis system.

OSMO FEED

 

industrial LINE

 

APPLICATION PURITY GRADE MODEL

   

 BASE VERSION
 Power systems for ultrapure water, 
 autoclaves, boilers in general. 
 Glassworks rinsing 
 Power supply steam generators 
 Ultrasound, thermostatic baths 

 DEMI VERSION
 General laboratory use
 Colorimetric analysis and qualitative
 Preparation / dilution reagents
 Glassware rinsing
 Thermostatic baths power
 Industrial uses: preparation waters
 of process

 TS-DEMI2 VERSION
 Spectrophotometric analysis in the
 atomic absorption
 HPLC chromatography
 Colorimetric analysis and qualitative
 Preparation / dilution reagents
 Feeding for water systems
 Ultra-pure, autoclaves, boilers in
 general.

 Glassware washer supply
 Power steam generators
 Ultrasonic, thermostatic baths

QUALITY STANDARD

RO VERSION (reverse osmosi only)


purified water, produced only
with reverse osmosis system.

DEMI VERSION

ISO 3696: grade  3
ASTM: type 3
NCCLS: type 3

TS-DEMI2 VERSION

ISO 3696: grade  2
ASTM: type 2
NCCLS: type 2
EP: conform

EL. RESISTIVITY SPEC. 25°C

Demi Vers. 5 MOhm.cm
Demi2 Vers. 10-18 MOhm.cm

RO 30 EL-TS

RO 60 EL-TS

RO 90 EL-TS

 

 BASE VERSION
 Power systems for ultrapure water, 
 autoclaves, boilers in general. 
 Glassworks rinsing 
 Power supply steam generators 
 Ultrasound, thermostatic baths 

 DEMI VERSION
 General laboratory use
 Colorimetric analysis and qualitative
 Preparation / dilution reagents
 Glassware rinsing
 Thermostatic baths power
 Industrial uses: preparation waters
 of process

 TS-DEMI2 VERSION
 Spectrophotometric analysis in the
 atomic absorption
 HPLC chromatography
 Colorimetric analysis and qualitative
 Preparation / dilution reagents
 Feeding for water systems
 Ultra-pure, autoclaves, boilers in
 general.

 Glassware washer supply
 Power steam generators
 Ultrasonic, thermostatic baths

QUALITY STANDARD

RO VERSION (reverse osmosi only)


purified water, produced only
with reverse osmosis system.

DEMI VERSION

ISO 3696: grade  3
ASTM: type 3
NCCLS: type 3

TS-DEMI2 VERSION

ISO 3696: grade  2
ASTM: type 2
NCCLS: type 2
EP: conform

EL. RESISTIVITY SPEC. 25°C

Demi Vers. 5 MOhm.cm
Demi2 Vers. 10-18 MOhm.cm

RO 160 EL-TS

RO 250 EL-TS

 

 BASE VERSION 
 Food industry
 Fine chemical industry (detergents)
 Nurseries of plants. preparation or 
 acidic waters poor of salts
 Industrial laundries
 Autoclaves, steam boilers in
 
general

 BiOs VERSION
 
Pharmaceutical industry
 Rinse glassware and optical
 lenses for rinsing 
 Finished gen. galvanic Industry
 Preparing industrial reagents 
 General Industrial user, 
 process water 

 BiOs-EDI VERSION
 
Electronic Industry
 G
alvanic fine industry
 Production chemical reagents for
 laboratory
 Medical Technology
 General industrial uses,
 process water
 As indicated for the BIOS Version

QUALITY STANDARD

RO VERSION (reverse osmosi only)


purified water, produced only
with reverse osmosis system.


BiOs VERSION

ISO 3696: grade  3
ASTM: type 3
NCCLS: type 3
EP: gener. conform

BiOs-ED versionI

ISO 3696: grade 2
ASTM: type 2
NCCLS: type 2
EP: conform

RESISTIVITA' EL. SPEC. 25°C

Vers. BiOs-EDI 10-18 MOhm.cm

RO 400 EL-TS

RO 750 EL-TS

RO 1000 EL-TS

RO 1500 EL-TS

RO 4000-8000-12000 EL-TS 

 

 
 I
ndustrial appication 
 in heigt precision
 Scientific reserce
 Feed critical plants
 the big laboratories

QUALITY STANDARD

ISO 3696: gradE 1
 ASTM: type 1
 NCCLS: type 1


EL. RESISTIVITY SPEC. 25°C

18 MOhm.cm

Refiner INDUSTRY

 

print guide to selection of the product

AVVISO: Questo sito utilizza cookies; continuando a navigare sul nostro sito, accetti implicitamente l'utilizzo dei cookies