TECHNICAL FEATURES | ||
- operative pressure RO elements | bar 8-9 |
|
- DAILY PRODUCTION | mc 15-18 |
|
- min. feed pressure | bar 2,5 |
|
- max feed pressure | bar 5,5 |
|
- range of temperature of water to be treated | °C 5-35 | |
- HOURLY PRODUCTION | lt/h 1500 | |
- hidraulic connection | IN OUT DRAIN |
2" 3/4" 3/4" |
- electric power | V AC 380 |
TECHNICAL SPECIFICATION WATER TO BE TREATED | DIMENSIONS | |||
TDS | ppm 500 | Lenght | max cm 160 | |
Total hardness | °F 30 | Width | max cm 87 | |
Iron | ppb 200 | Height | max cm 140 | |
Manganese | ppb 50 | |||
Chlor | ppm 0,1 | |||
SDI | <5 | |||
Total bacteria UFC/ml | <5 |
Storage tanks PE HD, anti-dust system with a capacity of 2000, 3000 LITERS regulated by 2 magnetic sensors levels, one in principle (block) and a minimum (restart production) compatible with the PLC software. a third sensor can be installed to indicate a level below the minimum due to accidental stop of the plant.
Support for the storage tank. Stainless steel AISI 304, complete with support for lower repressurization pump (if required).
Function meter, managed directly by the PLC, to achieve precision coverages. The external signal 'provided by a water meter Teflon-coated, the start of the machine is manual. The setting of the volume is easily adjustable using the keypad.
Repressurization pumps, both type BOOSTER low voltage complete switch and fast connection; either type pump in stainless steel, 220V power supply and control board for automatic operation.
UV sterilizer, made with outer jacket in AISI 304 or 316 on request, complete germicidal lamp, quartz and ballast power. 24 Vac power supply (power supply included).Can be installed on the water line produced or system recovery in pressure.
Anti-bacterial filter, composed of a 2-piece container, vessel inspection and transparent PE pleated cartridge, having a degree of 0.2 micron absolute filtration.
ULTRAFILTRATION CAPSULE. Capsule debacterizzante/depirogenante, type hollow fiber capillaries, filtration 10,000 Dalton.
Direct management of the operational elements:
- solenoid valve input
- pump overpressure
- flushing system Programmable membrane
- Program protection through password
- Displaying messages and data on LCD display
- Timer programming function can only be set PC (optional)
print RO 1500 EL