TECHNICAL FEATURES | ||
- operative pressure RO elements | bar 8-9 |
|
- DAILY PRODUCTION | mc 4-6 |
|
- min. feed pressure | bar 2,5 |
|
- max. feed pressure | bar 5,5 |
|
- range of temperature water to be treated | °C 5-35 | |
- HOURLY PRODUCTION | lt/h 400 | |
- hydraulic connections | IN OUT DRAIN |
1"1/2 1/2 1/2 |
- electric power | V AC 380 |
TECHNICAL SPECIFICATION WATER TO BE TREATED | DIMENSIONS | |||
TDS | ppm 500 | Lenght | max cm 53 | |
Total Hardness | °F 30 | Width | max cm 64 | |
Iron | ppb 100 | Height | max cm 137 | |
Manganese | ppb 5 | |||
Chlor | ppm 0,1 | |||
SDI | <5 | |||
Total bacteria tot. UFC/ml | <5 |
Storage tanks PE HD, anti-dust system with a capacity of 500, 1000, 2000 liters regulated by 2 magnetic sensors levels, one in principle (block) and a minimum (restart production) compatible with the PLC software. a third sensor can be installed to indicate a level below the minimum due to accidental stop of the plant.
Support for the storage tank. Stainless steel AISI 304, complete with support for lower repressurization pump (if required).
Function flow meter, managed directly by the PLC, to achieve precision coverages. The external signal 'provided by a water meter Teflon-coated, the start of the machine is manual. The setting of the volume is easily adjustable using the keypad.
Repressurization pumps, both type pump in stainless steel, 220V power supply and control board for automatic operation.
UV sterilizer, made with outer jacket in AISI 304 or 316 on request, complete germicidal lamp, quartz and ballast power. 24 Vac power supply (power supply included).Can be installed on the water line produced or system recovery in pressure.
Anti-bacterial filter, composed of a 2-piece container, vessel inspection and transparent PE pleated cartridge, having a degree of 0.2 micron absolute filtration.
The electrical panel is in IP 65, is run entirely by PLC interfaced with PC, both for programming and for self-diagnosis of the operational phases. There is also a digital conductivity meter operation and reading, to 2 decimal places, for reading online the quality of the water produced..
You can use the camera in manual mode, in which the start-up and stop are operated by the operator, or automatically with level control tank with 2 sensors (min, max).
A visual highlight the various types of alarm: water quality due to depletion membranes; need replacement cartridge pre-filter sediment or post-filter 0.2 microns (optional).
Operational characteristics of the control panel
Direct management of the operational elements:
- solenoid valve input
- pump overpressure
- flushing system Programmable membrane
- Program protection through password
- Displaying messages and data on LCD display
- Timer programming function can only be set PC (optional)
print RO 400 mp